Chinese | English

厂家logo
E-MAIL:15230713671@163.com           TEL:0086-17761570021
    INDUCTION PIPE EXPANDING
    Current position: HOME> Mechanical equipment>

    Intermediate frequency heating tube expander

    Intermediate frequency heating tube expander

    Mechanical parameters

    Type

    3”—12”

    8”—24”

    16”—30”

    20”—36”

    30”—48”

    Pipe wall thickness

    Sch80

    Maximum pressure

    31.5MPa

    Pressure of work

    25 MPa

    Working speed

    0—1000mm/min

    Fast speed back

    1500—2000mm/min

    Inner diameter of

    hydraulic

    180*2

    250mm*2

    360mm*2

    320mm*4

    360mm*4

    Hydraulic cylinder

    stroke

    6500mm

    6500mm

    6500mm

    6500mm

    6500mm

    Hydraulic cylinder

    thrust

    60T*2

    120T*2

    250T*2

    200T*2

    250T*4

    The motor power

    22.5kw

    46kw

    48.5kw

    75kw

    100kw

    Intermediate

    Frequency power

    Supply required

    250kwa

    400kwa

    600kwa

    800kwa

    1000kwa

     

    Mechanical video

    Equipment details

    Intermediate frequency heating tube expander

     

    Principle of tube expansion: the use of electromagnetic induction, the steel tube heating, resulting in deformation;

    Process of tube expansion: the inner wall of the steel tube to be expanded is brushed with lubricant the steel tube (with fixed mandrel) is fixed on the corresponding platform heating mandrel, push the steel tube to the mandrel the steel tube meets high temperature mandrel, easy to deform, with the size of the radius of the mandrel finally fixed shape;

    The main components of the machine: frame motor cone punch chuck hydraulic system;

    Scope of application: diameter range of steel tube: 21mm -- 1620mm;The thickness range of steel tube wall: 3mm -- 100mm;

    The advantages and disadvantages:

    Advantages: save manpower, protect the internal structure of steel tube, steel tube has a wide range of materials, suitable for large steel tube, convenient machine operation;

     

    Disadvantages: not suitable for small steel tube, forming time is longer, smear lubrication is not convenient;